Installation Instructions
Heat Bank Thermal Store System D - Indirect, Sealed Primaries

3331-2  14/02/01

Heat Bank Thermal Store System  
HBPP System D  
Everest combination unit  
Single Heat Exchanger (30 ltr/min)  
Indirect  
40mm Foam Insulation  
High duty primary coil  
Y-Plan primary controls  
Sealed primary system  
8 litre Primary Expansion Vessel  
Fitted programmer  
Fitted Primary Pump, 5m head  
All fitted controls are wired  
Thermostatic Blending Valve 22mm  
Backup Immersion Heater  
PCB Wiring Centre  
Primary Filling Loop  
Cased  


2   Plate Heat Exchanger
3   Heat Exchanger Pump
4   Flow Switch
5   Thermostatic Blending Valve, Mixcall III
6   Manual Air Vent
7   Automatic Air Vent
8   Filling Vent
9   Feed to Ball Valve
10  Isolating Valve
11  Y-Pattern Strainer (supplied loose)
12  Overflow
13  Cold Feed / Expansion
14  Immersion Heater 3kW Incaloy with Stat
16  Cold Mains In, 22mm
17  Hot Mains Out, 22mm
18  Drain Cock
19  Flow From Boiler
21  Flow to Primary Coil
22  Return from Primary Coil
23  Flow to Heating Circuit
26  Primary Pump UPS 15/50
29  Primary Coil Balancing Valve
30  Primary Expansion Vessel 8 litres
31  Primary Filling Point, with Check Valve
32  Pressure Relief Valve with Gauge 3 bar 1/2''
33  Programmer Danfoss CP715
35  Three Port Mid Position Valve
38  Cylinder Thermostat
42  Wiring Centre

 

Unit ID

HBPP500-180-D3331-2

Capacity

180

Base Diameter

500

Overall Diameter

580

Height

1250